Overview
This instrument is no longer available.
Maximum profiling range |
N/A |
Distance from probe |
0.05 m, 0.1 m (field probe) |
Sampling volume diameter |
6 mm |
Sampling volume height (user-selectable) |
3-15 mm |
Cell size |
N/A |
Velocity range* |
±0.03, 0.1, 0.3, 1, 2.5, 4 m/s (software-selectable) |
Adaptive ping interval |
N/A |
Accuracy |
±0.5% of measured value ±1 mm/s |
Velocity precision |
N/A |
Sampling rate (output) |
1-25 Hz (Std firmware),1-200 Hz (Plus firmware) |
Internal sampling rate |
N/A |
* The velocity range is not the same in the horizontal and vertical direction. Please refer to the configuration software. |
Minimum range |
N/A |
Maximum range |
N/A |
Cell size |
N/A |
Accuracy |
N/A |
Sampling rate |
N/A |
Acoustic frequency |
10 MHz |
Resolution |
Linear scale |
Dynamic range |
25 dB |
Temperature: |
Thermistor embedded in probe |
Temp. range |
-4 to +32 °C |
Temp. accuracy/resolution |
1 °C/0.1 °C |
Temp. time response |
5 min |
Compass: |
N/A |
Accuracy/resolution |
N/A |
Tilt: |
N/A |
Accuracy/resolution |
N/A |
Maximum tilt |
N/A |
Up or Down |
N/A |
Pressure: |
N/A |
Standard range |
N/A |
Accuracy/precision |
N/A |
No. of channels |
N/A |
Supply voltage to analog output devices |
N/A |
Capacity (standard): |
N/A |
Data record |
N/A |
Accuracy |
N/A |
Backup in absence of power |
N/A |
I/O |
RS-232 |
Communication baud rate |
300-115 200 Bd |
Recorder download baud rate |
N/A |
User control |
Handled via ”Vectrino” software, ActiveX® function calls, or direct commands |
Analog outputs |
3 channels standard, one for each velocity component |
Output range |
0–5 V, scaling is user-selectable0 |
Synchronization |
RS-485, start on sync, sample on sync,transmit on sync (Plus Firmware) |
Bulkhead |
MCBH-12-FS, bronze |
Cable |
PMCIL-12-MP – see also options below |
Functions |
Deployment planning, instrument configuration, data retrieval and conversion (for Windows®) |
Software |
Polysync |
I/O |
RS 232–USB support for devices with 1, 2, 4, and 8 serial ports |
DC input |
12-48 V DC |
Maximum peak current |
2.5 A at 12 V DC (user-selectable) |
Max. consumption |
1.5 W at 200 Hz |
Typical consumption, 4 Hz |
N/A |
Sleep consumption |
N/A |
Transmit power |
N/A |
Battery capacity |
N/A |
New battery voltage |
N/A |
Data collection capacity |
N/A |
Operating temperature |
-4 to +40 °C |
Storage temperature |
-15 to +60 °C |
Vibration |
IEC 60068-1/IEC60068-2-64 |
Depth rating |
20 m |
Standard model |
POM housing. Stainless steel (316) probe and fasteners |
Maximum diameter |
66 mm |
Maximum length |
350 mm (housing only), 365 mm (fixed stem) |
Weight in air |
1.2 kg (1.3 kg with field probe) |
Weight in water |
Neutral (0.1 kg with field probe) |
4-beam down-looking probe or side-looking probe. Fixed stem or 1 m flexible cable |
|
10, 20, 30 or 50 m cable with Impulse underwater connector |
|
RS 232–USB converter (one-to-one, four-to-one or eight-to-one) |
|
Standard or Vectrino Plus firmware |
|
Combined transportation and storage case |