Overview
The DVL 333 is a long-range Doppler Velocity Log that benefits from increased range with no compromise in performance or form factor. It allows vehicles to maintain bottom lock in a greater range of environments, increasing mission duration on long-range subsea vehicles. This 333 kHz DVL is used by innovators in the uncrewed vehicle sector looking to expand vehicle capabilities into new environments.
- Currents
- Bottom track
Highlights
-
Bottom track from 0.1-375 m range
-
Per-ping and per-beam data quality estimates
-
No change in form factor compared to higher-frequency options
Usage
-
Large UUVs/ AUVs operating at high altitudes in deep water
-
Deep-water large ROVs with high accuracy and long range requirements
-
Increase range of vehicles with existing DVL500 without vehicle redesign
Integration
With the longest range of the Nortek DVL family, this 6000m rated survey-grade DVL is equipped for easy integration with leading INS systems to create a robust, reliable navigation system with maximized range. As with all of Nortek's DVLs, the DVL 333 is compatible with top control software including EIVA, Seebyte and Greensea.
Reliability
Tested in demanding conditions in the Oslo fjord, the DVL 333 has a proven track record in areas of variable bathymetry and conditions. The water track feature provides a velocity backup if the bottom becomes out of range. The spectrum analyzer assures thorough system level integration.
Results
The DVL 333 provides reliable navigation in the most demanding conditions across multiple platforms. The addition of simultaneous current profiles improves operational safety and allows opportunistic oceanographic data collection.
Single ping std @ 1.5 m/s |
0.8 cm/s at 1/2 max altitude |
Long-term accuracy (1) |
±0.1% / ±0.1 cm/s (export-controlled), >1% (license-free) |
Minimum altitude |
0.1 m |
Maximum altitude |
375 m (2) |
Velocity resolution |
Better than 0.01 mm/s |
Maximum ping rate (3) |
8 Hz |
(1) Following standard calibration procedures |
|
(2) Bottom-track distance dependent on bottom type |
|
(3) Inquire for more options |
Minimum accuracy |
0.3% of measured value ± 0.3 cm/s |
Minimum range |
4.0 m |
Minimum accuracy |
0.3% of measured value ± 0.3 cm/s |
Velocity resolution |
0.1 cm/s |
Interval |
User-specified Nth ping |
Maximum range |
100 m |
Blanking |
0.5 m |
Cell size |
0.5-4.0 m |
Max # cells |
140 |
Operating temperature |
-4 to +40 °C |
Storage temperature |
-20 to +60 °C |
Vibration |
IEC60068-2-64 |
EMC approval |
IEC/EN 61000-6-2, 61000-6-3 |
Depth rating |
6000 m |
Weight |
7.0 kg |
Weight in water |
4.1 kg |
Height |
203 mm |
Diameter |
ø186 mm |
Frequency of operation |
333 kHz |
Beam width |
4.3° |
Configuration |
4-beam Janus array convex transducer, 25° beam angle |
Internal memory |
16 GB / 64 GB optional |
Bandwidth |
25% centered at transmit frequency |
Serial (either serial or ethernet) |
Configurable RS-232 or RS-422 Subconn connector, 8-pin male |
Ethernet |
10/100 Mbits Auto MDI-X. TCP/IP, UDP/IP, HTTP protocols. Fixed IP / DHCP client /Auto IP address assignment. UPnP and Nortek proprietary instrument discovery over Ethernet. IEEE1588/PTP and NTP for absolute time stamping. Multiple simultaneous data format transmission possible. |
Data formats |
Nortek proprietary w/ 1 ms time stamp accuracy, NMEA0183. OD0, PD4, PD5, PD6 |
Trigger |
Internal 1, 2, 3, 4, 5, 6, 7 or 8 Hz or Trigger In. Trigger option through command (Ethernet or serial) External TTL or 485 lines: (configurable Rising/Falling/Edges) |
Pressure |
0.1% FS /precision better than 0.002% of full scale per sample |
Temperature |
-4° to +40 °C ± 0.1 °C |
DC input |
12-48 V |
Maximum continuous current |
1.5 A |
Average power |
4.0 W (4) |
(4) Power based on 1 Hz sampling and altitude with greatest transmit pulse. |
Standard models |
POM and titanium housing |
DVL 333 - 300m
4 beam head
Titanium housing, 6000m
16 GB SD card data logger
64 GB
Pressure sensor 0-10 m, 0,1%
Pressure sensor 0-20 m, 0,1%
Pressure sensor 0-30 m, 0,1%
Pressure sensor 0-50 m, 0,1%
Pressure sensor 0-100 m, 0,1%
Pressure sensor 0-200m, 0,1%
Pressure sensor 0-300m, 0,1%
Cable, 8 pin female ethernet AD2CP with RS485 trigger
Cable, 8 pin female serial AD2CP with RS485 trigger
Cable, 8 pin female ethernet AD2CP with TTL trigger
Cable, 8 pin female serial AD2CP with TTL trigger
Bottom track
Current profiles, 4 beams