Overview
The Aquadopp Profiler is a highly versatile Acoustic Doppler Current Profiler (ADCP) available in three profiling range options, from < 1 m to > 85 m. The 2 MHz version has a current profiling range of up to 10 m. Designed for simple yet powerful operation, this current profiler is packed with features used by engineers and researchers to enable accurate and effective hydrodynamic data collection in a variety of environmental conditions.
The upgraded Aquadopp Profiler design offers improved noise immunity as well as 6% broadband measurements and “hibernation mode” between measurements, enabling precise data collection with lower power consumption. Increased internal battery storage extends potential deployment time.
See the details of the Generation 2 Aquadopp updates in the release notes here.
- Currents
- Waves
Highlights
-
Up to 10 m current profiling range
-
Optional right-angle head for measurements close to boundaries or in shallow water
-
Pressure-based (PUV) directional wave measurements
-
LED blinks when pinging for peace of mind during deployment
Usage
-
Near-bed current profiles with fine vertical resolution
-
Mean flow measurements with a focus on ease of use and simplicity
-
Measurements in areas with strong variations in flow speeds
-
Projects with needs for both high-resolution and normal-range current measurements with optional HR
-
Measurements of waves and currents from a single instrument
-
Studies of tidal currents
Setup
The 2MHz Aquadopp Profiler, designed for current measurements in shallow water (offering a 10m profiling range), is set up using the Nortek deployment software, enabling users to customize measurement schemes and assess power requirements.
Deployment
Compact size and an optional right-angle head allow for very near-bed deployments, maximizing water column coverage in shallow areas. Teams of all sizes can deploy an Aquadopp Profiler successfully.
Data
Nortek postprocessing software and/or display software is available for review, visualization, and processing of data, after deployment or in real time.
Nominal profiling range |
10 m |
Cell size |
0.1-2 m |
Maximum number of cells |
200 |
Minimum blanking |
0.2 m |
Velocity range (along beam) |
±1 m/s, ±2.5 m/s, ±5 m/s |
Velocity range (horizontal) |
±2.3 m/s, ±5.75 m/s, ±11.5 m/s |
Accuracy |
±1% of measured value ±0.5 cm/s |
Horizontal velocity precision (consult instrument SW) |
Typ. 1 cm/s |
Maximum sampling rate (output) |
1 Hz |
Wave measurements |
PUV (optional) |
Sampling |
Same as velocity |
Resolution |
0.5 dB |
Dynamic range |
90 dB |
Transducer acoustic frequency |
2 MHz |
Number of beams |
3 (see GA drawings for angles) |
Beam width |
0.85° (1.7° total) |
Maximum profiling range |
4.0 m |
Cell size |
0.01-0.13 m |
Minimum blanking |
0.1 m |
Maximum number of cells |
256 |
Velocity range |
3 cm/s - 0.65 m/s |
Range velocity limitations |
Product of profiling range and velocity should not exceed 0.12 m2/s |
Accuracy |
±1% of measured value ±0.5 cm/s |
Max. sampling rate |
8 Hz |
Temperature: |
|
Temp. range |
-4 to +40 °C |
Temp. accuracy/resolution |
0.1 °C/0.01 °C |
Temp. time response |
<1 min |
Compass: |
Solid state magnetometer |
Accuracy/resolution |
<2° for tilt < 30° /0.01° |
Tilt: |
Solid state accelerometer |
Accuracy/resolution |
0.2° for tilt <30° / 0.01° |
Maximum tilt |
Full 3D |
Up or Down |
Automatic detect |
Pressure: |
Piezoresistive |
Range |
30 m / 100 m / 500 m |
Accuracy/precision |
0.5% FS / 0.005% of full scale |
Capacity |
16 GB |
Accuracy |
±1 min/year |
Backup in absence of power |
4 weeks |
I/O |
RS-422 (inquire for RS-232) |
Communication baud rate |
9600 Baud - 1.2 Mbaud (default 115200 Baud) |
User control |
Nortek Deployment Software or direct ASCII commands, with binary or ASCII data output |
Operating system |
Cross platform |
Functions |
Deployment planning, instrument configuration, data retrieval and conversion. Online data display |
DC input |
9-24 VDC |
Absolute maximum DC input |
26 VDC |
Maximum peak current |
4.5 A |
Power consumption |
Consult Nortek Deployment Software |
Sleep current |
< 40 uA |
Transmit power |
Adjustable |
Internal battery capacity |
1-3 x 50 Wh (Alkaline); 2-3 x 165 Wh (Lithium), 1-3 x 76 Wh (Li-Ion) |
Battery weight |
430g per 50 Wh (Alkaline); 380g per 165 Wh (Lithium); 300g per 76 Wh (Li-ion) |
Operating temperature |
-5 to +40 °C |
Storage temperature |
-20 to +60 °C |
Shock and vibration |
Shock: IEC 60068-2-27, Vibration: IEC 60068-2-64 |
EMC |
EN IEC 61000-6-2:2019, EN IEC 61000-6-4:2019 |
Depth rating |
500 m |
Bulkhead (Impulse) |
MCBH-8-FS Brass |
Cable |
PMCIL-8-MP on 5 m (default) polyurethane cable |
Standard model |
POM, Naval Brass, Titanium Gr. 5, Epoxy |
Maximum housing diameter |
75 mm |
Maximum length |
S2VP: 589 mm; S2SP: 634 mm |
Weight in air (without batteries) |
S2VP: 2500 g; S2SP: 2710 g |
Weight in water (without batteries) |
S2VP: -120 g; S2SP: -50 g |
Weight in air, short housing (without batteries) |
S2VP: 1900 g, S2SP: 2100 g |
Weight in water, short housing (without batteries) |
S2VP: 330 g, S2SP: 400 g |
S2VP |
Shallow water, 2MHz, Vertical orientation, Profiler |
S2SP |
Shallow water, 2MHz, Side-looking orientation, Profiler |
Cable length |
0-10m; 10-50m; 50-500m |
Power wire gauge |
20AWG; 20AWG; 18AWG |
Hardware |
Standard; Standard; Long cable kit |
Input voltage |
9-24VDC; 24VDC +/-0,5; 48VDC +2/-5 |
Absolut maximum DC input |
26 VDC; 26 VDC; 51 VDC |
Communication |
RS232/RS422/115200; RS232/RS422/115200; RS422/115200 |
Aquadopp Profiler 2 2MHz
2 MHz Standard head
2 MHz Right-angle head
Standard housing for three batteries
Short housing for one battery
Pressure sensor, 0-30 m
Pressure sensor, 0-100 m
Pressure sensor, 0-500m
5m PMCIL-8-MP Serial cable for Aquadopp 2
10m PMCIL-8-MP Serial cable for Aquadopp 2
20m PMCIL-8-MP Serial cable for Aquadopp 2
30m PMCIL-8-MP Serial cable for Aquadopp 2
40m PMCIL-8-MP Serial cable for Aquadopp 2
50m PMCIL-8-MP Serial cable for Aquadopp 2
New features, fixes and functionality
The standard deployment software for Nortek Aquadopp and Aquadopp Profiler instruments purchased after October 2023.
The software can be launched from your web browser, installed from Microsoft Store or downloaded as an offline installer file.
Post-processing software for Aquadopp Generation 2, AWAC Generation 2, and Signature series instruments.
Set of Anti-fouling patches for Aquadopp
This set is suitable for Aquadopp 300 m, Aquadopp Profiler 1MHz, Aquadopp Profiler 2MHz and Eco
Battery pack, 10-pack, 12 V - 165 Wh, lithium - for use with Aquadopp Generation 2
This battery can be used inside the main canister of your Nortek instrument.
Battery pack, 10-pack, 13.5 V - 50 Wh, alkaline - for use with Aquadopp Generation 2
This slim battery can be used inside the main canister of your Nortek instrument.
Battery pack, 5-pack, 12 V - 165 Wh, lithium - for use with Aquadopp Generation 2
This battery can be used inside the main canister of your Nortek instrument.
Battery pack, 5-pack, 13.5 V - 50 Wh, alkaline - for use with Aquadopp Generation 2
This slim battery can be used inside the main canister of your Nortek instrument.
Battery, 12 V - 165 Wh, lithium - for use with Aquadopp Generation 2
This battery can be used inside the main canister of your Nortek instrument.
Battery, 13.5 V - 50 Wh, alkaline - for use with Aquadopp Generation 2
This slim battery can be used inside the main canister of your Nortek instrument.
Battery, 75Wh Li-ion rechargeable
This small, rechargeable battery can be used in the main canister of your instrument.
Charger for Li-ion batteries